protector unit

B2B,Business to Business Marketplace,Outsourcing Directory,B2B Website
Business to Business Marketplace
B2B Marketplace, Outsourcing Directory, B2B Website
tmcards
Search Search Tips
   
 
Ningbo Chuanglian Telecommunication Equipment Co protector unit

Ningbo Chuanglian Telecommunication Equipment Co

 
 
 

Selling Lead

   


protector unit - May, 12 2010

1. Mainly consist of crust, gas or solid tube arrester, thermal resistance PTC, reed and base pin;
2. Cladding:phosphorus bronze and silver plating(20-40uinch);
3. The performance of anti-burn ABS(UL94V-0), Combustibility achieved GB/T 5169.7-1985 standard;
4. Insulated resistance:under satndard atmospheric pressure, the insulated resistance is not lower than 1, 000M ohm;
5. Over voltage and over currency protection:meeting the industry standard;
6. The performance of fail safe:when discharge achieve 2.5Ar.m.s.
The a line or b line should be 5-15s internal earthing in the discarge loop;
7. Eletric specifications
Protector Characteristics Requirements


Gas/Solid Tude DC spark-over voltage Udc=220v
Impulse spark-over voltage Umax≤800V(1000V/us)
ARC Voltage 1000M ohm to 100 VDC


PTC Thermistor Resistance DC ≤22Ω
Current of holding Lower to 100 mA after testing duting 1 hour at 30℃, 60/DC
Trip Time 1.5 sec.at 1AMP

Company Name : Ningbo Chuanglian Telecommunication Equipment Co